Respir Care ; 68(12): 1639-1645, 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-37580124

RESUMO

BACKGROUND: Airway pressure is usually measured by sensors placed in the ventilator or on the ventilator side of the endotracheal tube (ETT), at the Y-piece. These remote measurements serve as a surrogate for the tracheal or alveolar pressure. Tracheal pressure can only be predicted correctly by using a model that incorporates the pressure at the remote location, the flow through the ETT, and the resistance of the ETT if the latter is a predictable function of Y-piece flow. However, this is not consistently appropriate, and accuracy of prediction is hampered. METHODS: This in vitro study systematically examined the ventilator pressure in dependence of compliance of the respiratory system (CRS), inspiratory time, and expiratory time during pressure-controlled ventilation by using a small intratracheal pressure sensor and a mechanical lung simulator. Pressures were measured simultaneously at the ventilator outlet, at the Y-piece, and in the trachea during pressure-controlled ventilation with a peak inspiratory pressure of 20 cm H2O and a PEEP of 5 cm H2O while changing CRS (10, 30, 60, 90, and 100 mL/cm H2O) and varying inspiratory time and expiratory time. RESULTS: Tracheal pressures were always lower (maximum 8 cm H2O during inspiration) or higher (maximum 4 cm H2O during expiration) than the pressures measured proximal to the ETT if zero-flow conditions were not achieved at the end of the breathing cycles. CONCLUSIONS: Dependent on CRS and the breathing cycle, tracheal pressures deviated from those measured proximal to the ETT under non-zero-flow conditions. Intratracheal pressure and pressure curve dynamics can differ greatly from the ventilator pressure, depending on the ventilator setting and the CRS. The small pressure sensor may be used as a measurement method of tracheal pressure via integration onto an ETT.


Assuntos
Respiração com Pressão Positiva , Traqueia , Humanos , Respiração com Pressão Positiva/métodos , Respiração Artificial/métodos , Ventiladores Mecânicos , Respiração , Intubação Intratraqueal
2.
Artif Organs ; 43(2): 159-166, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30084492

RESUMO

The most common technical complication during ECMO is clot formation. A large clot inside a membrane oxygenator reduces effective membrane surface area and therefore gas transfer capabilities, and restricts blood flow through the device, resulting in an increased membrane oxygenator pressure drop (dpMO). The reasons for thrombotic events are manifold and highly patient specific. Thrombus formation inside the oxygenator during ECMO is usually unpredictable and remains an unsolved problem. Clot sizes and positions are well documented in literature for the Maquet Quadrox-i Adult oxygenator based on CT data extracted from devices after patient treatment. Based on this data, the present study was designed to investigate the effects of large clots on purely technical parameters, for example, dpMO and gas transfer. Therefore, medical grade silicone was injected into the fiber bundle of the devices to replicate large clot positions and sizes. A total of six devices were tested in vitro with silicone clot volumes of 0, 30, 40, 50, 65, and 85 mL in accordance with ISO 7199. Gas transfer was measured by sampling blood pre and post device, as well as by sampling the exhaust gas at the devices' outlet at blood flow rates of 0.5, 2.5, and 5.0 L/min. Pre and post device pressure was monitored to calculate the dpMO at the different blood flow rates. The dpMO was found to be a reliable parameter to indicate a large clot only in already advanced "clotting stages." The CO2 concentration in the exhaust gas, however, was found to be sensitive to even small clot sizes and at low blood flows. Exhaust gas CO2 concentration can be monitored continuously and without any risks for the patient during ECMO therapy to provide additional information on the endurance of the oxygenator. This may help detect a clot formation and growth inside a membrane oxygenator during ECMO even if the increase in dpMO remains moderate.


Assuntos
Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenadores de Membrana/efeitos adversos , Trombose/diagnóstico , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Desenho de Equipamento , Hemodinâmica , Humanos , Índice de Gravidade de Doença , Trombose/etiologia